Yaskawa#How to Use the Servopack ID Selector

This article provides a memo on how to use the ID Selector feature of Yaskawa’s SGDXS series.

The settings of the ID selectors (S1 and S2) can be used to identify Yaskawa SGDXS series EtherCAT SERVOPACKs. These switches are used for identifying EtherCAT slave devices.

These are the switches S1 and S2 on the actual unit. In the settings shown below, the Servo is configured to ID=2.

The mechanism for requesting ID for SERVOPACK identification is shown in the figure below.

This shows the state where Delta Motion’s EtherCAT module is connected to Yaskawa’s SGDXS series EtherCAT Servo drive. The Bus Mismatch error is displayed because the Hardware Configuration does not match the ID on the actual unit.

Check the Checkbox for Advanced Settings > Identification Checking > Check Identification, and enter the value set by the ID Selector in the number field.