Project#Beckhoff TwinCAT3 x Siemens S210 Servo Drvie_Part5

Last time, I used the Idevices function to exchange data from S71212F to Beckhoff IPC C6920 with Profinet. This time I’m going to step away from the main control and upload Beckhoff IPC data to WAGO Cloud via WAGO PFC Controller 720-8215 Modbus TCP.Let’s start!

Thanks!

Because of Beckhoff Japan ,Wago Japan and mana Design works that lend the devices to me – I can create this post.

Beckhoff Japan

IPC6920-005 was lent by Beckhoff Japan, a Japanese subsidiary of Beckhoff. Founded in 1980, Beckhoff Automation is a German company at the forefront of the introduction of open automation systems based on PC-based control technology.

Beckhoff Japan Corporation Beckhoff Automation Co., Ltd. established its head office in Yokohama in 2011 and the Nagoya office in 2017.

Here is the Home page of Beckhoff Japan.

https://www.beckhoff.com/ja-jp/

Mana Design Works

Siemens SINAMICS S210 was lent by Mana Design Works.

Mana Design Works is an official solution partner of Siemens ,headquartered in Osaka, and always make optimal proposals with Siemens CPUs, HMIs, Drives, Motion Controllers, and SCADA.

Here is the homepage of Mana Design works.

https://mndw.jp/

Wago Japan

750-8215 is lent by Wago Japan Co., Ltd. WAGO was started in 1951, a German company that has supported the field with the technologies of PUSH WIRE and CAGE CLAMP, and have contributed to industries around the world with terminal block technology. WAGO also has a PLC LINEUP, offering automation solutions with an emphasis on openness and flexibility.

Wago Japan Co., Ltd. is headquartered in Koto-ku, Tokyo.

https://www.wago.co.jp/

Video

English Version

Part4

Beckhoff.TwinCAT3 x Siemens S210 Servo Drive part4 – Idevices Configuration.EN

Part3

Beckhoff.TwinCAT3 x Siemens S210 Servo Drive part3 – PLCOPEN to Control the Drive in TwinCAT.EN

Part2

Beckhoff.TwinCAT3 x Siemens S210 Servo Drive part2 – Shared Devices,Profisafe.EN

Part1

Beckhoff.TwinCAT3 x Siemens S210 Servo Drive part1.EN

Japanese Version

Part4

Beckhoff.TwinCAT3 x Siemens S210 Servo Drive part4 – Idevices Configuration.JP

Part3

Beckhoff.TwinCAT3 x Siemens S210 Servo Drive part3 – PLCOPEN to Control the Drive in TwinCAT.JP

Part2

Beckhoff.TwinCAT3 x Siemens S210 Servo Drive part2 – Shared Devices,Profisafe.JP

Part1

Beckhoff.TwinCAT3 x Siemens S210 Servo Drive part1.JP

Reference Link

Japanese Version

Project#Beckhoff TwinCAT3 x Siemens S210 Servo Drvie_Part4
Project#Beckhoff TwinCAT3 x Siemens S210 Servo Drvie_Part3

Project#Beckhoff TwinCAT3 x Siemens S210 Servo Drvie_Part2 |

Project#Beckhoff TwinCAT3 x Siemens S210 Servo Drvie_Part1

English Version

Project#Beckhoff TwinCAT3 x Siemens S210 Servo Drvie_Part3

Project#Beckhoff TwinCAT3 x Siemens S210 Servo Drvie_Part2 |

Project#Beckhoff TwinCAT3 x Siemens S210 Servo Drvie_Part1 |

Implementation-1

Before actually connecting with TwinCAT, it is safer to first verify the Modbus TCP Slave function of the Wago PFC Controller. A free Modbus Scanner software is used from CAS.

Reference Link

Wago#Let’s Start with WAGOCloud!
Wago#e!COCKPIT Installation
Wago#e!COCKPIT Your First Program!
Wago#Using E!COCKPIT to update the CPU Firmware

E!EOCKPIT Side

Interface configuration

We will use Port1 as the IOT port and Port2 as the data collection port.

Define Variables

Open the Program Structure Tab.

The operation interface is very similar between E!COCKPIT and Codesys, Go to Application>Right Click>Create a Global Variable List. 

Enter the GVL name>add it.

GVL is inserted in your project.

Let’s Define some Register for the modbus TCP Server.

Hardware Configuration

Now we need to build the hardware configuration.

Add Modbus TCP

Check the Network view in your E!COCKPIT tools, go to Product Catalog >Open the MODBUS TCP Folder and Scroll down.

Drop the Generic_Modbus_Master into the network.

Modbus Master is inserted in your project.

Connect it

Let’s Connect the PFC controller to the Generic_Modbus_Master.Please Click the ETHERNET(ETHERNET).

Generic_Modbus_Masterにひっばります。

Connection is configured.

Check Communication Relationship

Just in case, click the gray LINE of Connection and click the button of Communication Relation.

You can see that Master is Generic_Modbus_Master and Slave is PFC Controller.

Configurator

Next, click PFC Controller and set Modbus Slave.

Click the Configurator button.

Modbus Configurator is shown.

Add Program variables

Right click the Program variables>Add From program.

The variables currently in the E!COCKPIT project are displayed.

Select GVL_ModbusData > OK.

Three array variables have been added from your User Program.

Basic Settings

Next, right-click PFC Controller and make detailed settings for Modbus Slave from Settings button.

Set Unit-ID to 1, select Always update for Update Variables, and finally set TCP Port to 502 in TCP Settings.

Downlaod

Finally, download the project with Connect from the NETWORK Tab.

Run

Let’s switch the CPU to Run Mode.

Check it

Let’s verify the connection with the Modbus Scanner Software.

Install tools

This time we will use a free software called CAS Modbus Scanner.

https://store.chipkin.com/products/tools/cas-modbus-scanner

Run the EXE File.

Next>.

Accept the license and click Next>.

Set the Install Path and proceed with Install.

Done!

CAS Modbus Scanner started.

Scan it

First, search for Wago Modbus Slave with the Discover function.

Select TCP Connection and set IP and Port of PFC Controller.

Press Start Scan to search the nodes.

Add Connection

Next, let’s add a Connection.

Right click > Add Connection.

Enter the IP and Port from the TCP Connection Field, and add the PFC Controller with “Add TCP Connection”.

Next, right-click > Add Device from the Connection you just added.

Match the Slave ID with the Unit-ID set on the E!COCKPIT side.

Slaves have been added. Finally, create a read task. Right-click > Add Task from Slave.

Select -Function 04, Offset 1, Length4>Add Request. If the connection is OK, 4 bytes of data can be read from 30001.

Implementation-2

E!COCKPIT Side

After the Connectivity of Modbus TCP Server is confirmed, we can implement the TwinCAT side to access the Modbus TCP Server.

Configuration

we just modify the registers in implementation-1.

And we’re-map the Register in the Modbus Editor.

Program

POU_Upload2WagoCloud

It’s not much different from the first chapter of WAGO CLOUD Tutorial, but this program collects multiple variables into one array and transfers them to WAGO CLOUD.

PROGRAM POU_Upload2WagoCloud
VAR
S210_1:ARRAY[0..9]OF WagoAppCloud.typVariableDescription;
S210_1_Collections:WagoAppCloud.typCollection;
Logger:WagoAppCloud.FbCollectionLogger;
Status:WagoSysErrorBase.FbResult;
END_VAR

VAR RETAIN
tSampleInvTime :TIME:=T#1S;
tPublishInvTime :TIME:=T#1S;
END_VAR
VAR bError:BOOL; bOperational:BOOL; bNotMoving :BOOL;END_VAR
//ID1
S210_1[0].sUnit:=’mm’;
S210_1[0].pAddress:=ADR(GVL_ModbusData.RegsReal[0]);
S210_1[0].eValueType:=WagoAppCloud.VVT_REAL;
S210_1[0].sTag:=’ActPos’;
S210_1[0].dwTypeId:=1;

//ID2
S210_1[1].sUnit:=’mm’;
S210_1[1].pAddress:=ADR(GVL_ModbusData.RegsReal[1]);
S210_1[1].eValueType:=WagoAppCloud.VVT_REAL;
S210_1[1].sTag:=’ActVel’;
S210_1[1].dwTypeId:=2;

//ID3
S210_1[2].sUnit:=”;
S210_1[2].pAddress:=ADR(GVL_ModbusData.RegsWord[0]);
S210_1[2].eValueType:=WagoAppCloud.VVT_WORD;
S210_1[2].sTag:=’Error’;
S210_1[2].dwTypeId:=3;

//ID4
S210_1[3].sUnit:=”;
S210_1[3].pAddress:=ADR(GVL_ModbusData.RegsWord[1]);
S210_1[3].eValueType:=WagoAppCloud.VVT_WORD;
S210_1[3].sTag:=’Operational’;
S210_1[3].dwTypeId:=4;

//ID5
S210_1[4].sUnit:=”;
S210_1[4].pAddress:=ADR(GVL_ModbusData.RegsWord[3]);
S210_1[4].eValueType:=WagoAppCloud.VVT_WORD;
S210_1[4].sTag:=’ActStationo’;
S210_1[4].dwTypeId:=5;

S210_1_Collections.dwCollectionId:=1;
S210_1_Collections.dwVariablesCount:=5;
S210_1_Collections.sName:=’S210 Data’;
S210_1_Collections.pPublishInterval:=ADR(tPublishInvTime);
S210_1_Collections.pSampleInterval:=ADR(tSampleInvTime);
S210_1_Collections.pVariableDescriptions:=ADR(S210_1);


Logger(
pCollections:=ADR(S210_1_Collections)
,dwCollectionsCount:=1
,oStatus=>Status
);
bError:=GVL_ModbusData.RegsWord[0]<>0;bOperational:=GVL_ModbusData.RegsWord[1]<>0;bNotMoving:=GVL_ModbusData.RegsWord[2]<>0;

PLC_PRG

Finally, we call the program from PLC_PRG on MAIN.

PROGRAM PLC_PRG
VAR

END_VAR

VAR RETAIN

END_VAR


POU_Upload2WagoCloud();

HMI

Create a simple screen on E!COCKPIT and transfer it to the PFC Controller.

The screen will be displayed in the same way on WAGO CLOUD.

TwinCAT Side

Reference Link

Beckhoff#TwinCAT3 TF6250 Modbus-TCP Function

Add Library

Go to PLC>References>Add Library to add a new library into your project.

Choose Tc2_ModbusSrv>OK.

Programs

Insert this program into POU_Main and call it in main.

POU_Modbus

This is a program to communicate with MODBUS TCP Slave of Wago PFC Controller. When bStart becomes True、 communication starts > First write Real Register, then write 16 Bit Integer Register > return infinite loop.

PROGRAM POU_Modbus
VAR

_MBWriteRegs :FB_MBWriteRegs;
bStart :BOOL;
RealRegister :ARRAY[0..3]OF REAL;
R_TRIG:R_TRIG;
bBusy,bError:BOOL;
nErrorID:UDINT;
TONs: ARRAY[0..2]OF TON;
iStep:INT;
END_VAR

CASE iStep OF
0:
IF bStart THEN
_MBWriteRegs.nMBAddr:=32000;
_MBWriteRegs.nQuantity:=SIZEOF(GVL_Modbus.RealRegister)/2;
_MBWriteRegs.cbLength:=SIZEOF(GVL_Modbus.RealRegister);
_MBWriteRegs.pSrcAddr:=ADR(GVL_Modbus.RealRegister);

iStep:=10;
END_IF
10:
IF _MBWriteRegs.bError OR _MBWriteRegs.bBusy THEN
iStep:=20;
END_IF
20:
TONs[0](IN:=TRUE,PT:=T#0.2S);
IF TONs[0].Q THEN
TONs[0](IN:=FALSE);
iStep:=30;
END_IF
30:
IF bStart THEN
_MBWriteRegs.nMBAddr:=32008;
_MBWriteRegs.nQuantity:=SIZEOF(GVL_Modbus.WordRegister)/2;
_MBWriteRegs.cbLength:=SIZEOF(GVL_Modbus.WordRegister);
_MBWriteRegs.pSrcAddr:=ADR(GVL_Modbus.WordRegister);

iStep:=40;
END_IF

40:
IF _MBWriteRegs.bError OR _MBWriteRegs.bBusy THEN
iStep:=50;
END_IF
50:
TONs[0](IN:=TRUE,PT:=T#0.2S);
IF TONs[0].Q THEN
TONs[0](IN:=FALSE);
iStep:=0;
END_IF
END_CASE


_MBWriteRegs(
sIPAddr:=’192.168.3.17′
,bExecute:=iStep = 10 OR iStep=40
,nTCPPort:=502
,nUnitID:=16#FF
,bBusy=>bBusy
,bError=>bError
,nErrId=>nErrorID
);

MAIN

In the MAIN POUs, we will call the previous POU_Modbus, and transfer the data of S210/S71200 to Real Register and 16Bit Integer Register.

PROGRAM MAIN
VAR
Axis :AXIS_REF;
END_VAR

VAR
PNController :FB_PNController_Status;
PNDevices_S210 :FB_PnDevices_Status;
PNDevices_S71200:FB_DataFromSiemens;
S210 :FB_MyS210;
Mode :eDUT_Mode;
autocmd:BOOL;
autosst :DINT;
istep:DINT;
TON :TON;

END_VAR


IF NOT PNDevices_S71200.STOOK THEN
istep:=0;
GVL_SystemHMI.PB.AutoStart:=FALSE;
autosst:=0;
END_IF


GVL_SystemHMI.PL.ModeAuto:=GVL_SystemHMI.PB.Mode = eDUT_Mode.Auto;
GVL_SystemHMI.PL.ModeManual:=GVL_SystemHMI.PB.Mode = eDUT_Mode.Manual;
GVL_SystemHMI.PL.Reset:=GVL_SystemHMI.PB.Reset;
GVL_SystemHMI.PL.PowerOn:=S210.qStatus.Operational;
GVL_SystemHMI.PL.AutoStart:=istep<>0;


IF GVL_SystemHMI.PL.ModeAuto THEN
Mode:=eDUT_Mode.Auto;
ELSIF GVL_SystemHMI.PL.ModeManual THEN
Mode:=eDUT_Mode.Manual;
END_IF;



IF Mode=eDUT_Mode.Auto THEN

CASE istep OF

0:
TON(IN:=GVL_SystemHMI.PB.AutoStart,PT:=T#1S);
IF TON.Q THEN
istep:=10;
TON(in:=False);
END_IF
10:
autosst:=1;
IF S210.qActualStation = 1 THEN
istep:=15;
autosst:=0;
END_IF
15:
TON(in:=TRUE,PT:=T#1S);
IF TON.Q THEN
TON(in:=FALSE);
istep:=20;
END_IF;
20:
autosst:=2;
IF S210.qActualStation = 2 THEN
istep:=10;
autosst:=0;
END_IF
END_CASE

ELSE
istep:=0;
autosst:=0;
END_IF


PNDevices_S71200.Reset(Execute:=GVL_SystemHMI.PB.Reset);

S210.iPNComOK:=PNController.Ready
AND PNDevices_S210.Ready
AND PNDevices_S71200.Ready

;

S210(
iEnable:=TRUE
,bServoON:=GVL_SystemHMI.PB.PowerOn
,bReset:=GVL_SystemHMI.PB.Reset
,Mode:=Mode
,bILAbs:=TRUE
,bILJog:=TRUE
,bILAbs:=TRUE
,bAutoAbsCmd:=autocmd
,iAutoStationCmd:=autosst
,Hmis:=GVL.Hmis
);


GVL_Modbus.RealRegister[0]:=S210.qActualPosition;
GVL_Modbus.RealRegister[1]:=S210.qActualVelocity;
GVL_Modbus.WordRegister[0].0:=S210.qStatus.Error;
GVL_Modbus.WordRegister[1].0:=S210.qStatus.Operational;
GVL_Modbus.WordRegister[2].0:=S210.qStatus.NotMoving;;
GVL_Modbus.WordRegister[3]:=UDINT_TO_WORD(s210.qActualStation);



POU_Modbus();

Wago Cloud Side

To be able to display the PFC Controller screen from WAGO CLOUD、 you need to install a little Plug-in.

Download Package

Access the below link and enter the information>Submit.

https://www.wago.com/global/requestDirectDownload?downloadFile=swreg_remote_access

Press the Download BUtton to Download the Software Packages.

Alternatively、 you can also download it from here as you will receive a Download Link from your email.

A Zip file is downloaded.

Software Packages of each PFC Controller ‘s firmware are zipped inside.

Install Software

Next、 let’s install Software Packages to the PFC Controller. Please access the WBM of the PFC Controller.

Go to Software Update>Click the Software File.

My PFC Controller’s firmware is higher than 20 and FW20UP Software Packages is chosen in here.

Press the install button to install the Software Packages.

Please wait a minute..

Done!

Restart

Let’s restart your Wago PFC Controller.

Result

Status

The status is shown as Critical if the connection is not established.

Online status is shown while the connection is established!

Collection

And we can see the S210 Data Collection is inside our collection.

Dashboard

And we can see the Speed/Error status in the Dashboard;)

If you want to list the data of the time column, click from the Dashboard Title>Inspect>Data.

HMI

The last is the HMI. The “Connect” button for Web Visualization and Web-based Management from Remote Access is now in green!

First, let’s take a look at the Web Visualization of the PFC Controller.

OK.

Username and Password are the same as WBM.

Done!

You can also see the PFC Controller Web Browser in Wago Cloud. In other words, it is possible to change the settings of the PFC Controller from Wago Cloud.

Video

Source Project Download

https://github.com/soup01Threes/TwinCAT3/blob/main/TwinCAT%20S210-part5.zip